Torbal BA Platform Series Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Waage Torbal BA Platform Series herunter. Torbal BA Platform Series User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - BA Platform and Remote Mount

BA Platform and Remote Mount Instruction Manual Model: BA30 - BA303 BA30C - BA303C BA30E – BA150E BA3M – BA15M BA3U – BA15U BA15W

Seite 2 - Table of Contents

- 9 - 5. After leveling the scale, you may plug the AC adaptor to the AC adaptor socket located in the rear of the scale. 6. When the AC adap

Seite 3 - Chapter 1: Cautionary Notes

- 10 - 1. The scale should be properly zeroed before weighing. Proper zeroing is indicated by the Zero Indicator (→0←) on the display. If the

Seite 4 - WARNING:

- 11 - • Parts Counting is used to count parts based on their established average piece weight. • Percent weighing is used to establish the re

Seite 5

- 12 - 8.1. Weighing 1. To begin weighing, press the power button ( ) to turn the scale ON. The scale will go through its initialization proce

Seite 6 - Chapter 2: Specifications

- 13 - 3. Once the stabilization indicator appears on the display, the container is ready to be tared. To tare the container, press the “T” button.

Seite 7 - Description

- 14 - 8.3. Extending the resolution 1. The resolution of the scale can be temporarily increased by pressing the HR key. This temporary increase in

Seite 8 - Chapter 4: Parts Description

- 15 - All BA Scales are equipped with AZSM, the “Auto Zero Setting Mechanism.” AZSM automatically maintains a center of zero and it is set to 0.5

Seite 9

- 16 - Functions Options: PCS Off ( PCsoff) Disables Parts Counting PCS On (pcs on) Enables Parts Counting PCS .. (PCS . .) Recalls the last Aver

Seite 10

- 17 - 4. Select “PCS on” by pressing the T key. 5. Available sample size options will alternate on the display. Press the T key to select a siz

Seite 11

- 18 - 10.2. Using a custom sample size 1. Place the counting container on the pan while in the weighing mode and press the T key to tare the conta

Seite 12

Table of Contents 1. Cautionary notes and precaution…...………………………………………………………………... 2 1.1 Important handling c

Seite 13 - Chapter 8: Weighing

- 19 - 5. Available sample size options will alternate on the display. Press the T key when “PC Set” is displayed. 6. A dashed line will be dis

Seite 14

- 20 - 10.3. Counting based on a known Individual Piece Weight (No Sample Size Required) 1. Place the counting container on the pan and press the

Seite 15

- 21 - 6. A dashed line will be displayed indicating to manually enter the exact individual piece weight of the counted parts. To manually enter the

Seite 16

- 22 - The BA Scales can operate in nine different units of measure: Grams (g), Kilograms (kg), Carats (ct), Pounds (lb), Newton, Grains, Ounces, O

Seite 17

- 23 - Function Options: PER Off ( Peroff) Disables Percent Weighing PER On (per on) Enables Percent Weighing Percent weighing is used to expre

Seite 18 - 17

- 24 - 5. Commands “PER OFF” and “PER ON” will be displayed sequentially. To proceed with percent weighing and set the reference sample weight, pres

Seite 19

- 25 - Function Options: Rec Off ( rECoff) Disables Recipe Weighing Rec On (reC on) Enables Recipe Weighing Rec Con (reCCon) allows to continue

Seite 20

- 26 - 5. The display will read 0 indicating that you may place the first ingredient into the container. Once the Weight of the ingredient stabilize

Seite 21

- 27 - 9. The total of all ingredients will be displayed. 10. To continue Recipe making press the Menu select the “Recipe” function, and then

Seite 22

- 28 - Function Options: CAL On ( CaL oN) Starts Quick Calibration. Recommended when calibrating with a single calibration weight. CAL Stp (CALS

Seite 23 - Carat penny

- 2 - Remember choose a proper location for you scale and to always handle the unit with care. The correct location and proper environment makes

Seite 24

- 29 - 4. The scale will perform a tare and the message “LOAD” will be displayed. 5. When the message “LOAD” is displayed, place the cali

Seite 25

- 30 - 14.2 Stepped Calibration (calibrating with multiple calibration weights.) 1. Press the MENU key, when the option “Calib” is displayed press

Seite 26

- 31 - 5. The scale will perform a tare and the message “LOAD” will be displayed indicating to place all calibration weights on the pan. After plac

Seite 27

- 32 - After a weighing transaction is completed, a result data receipt can be printed. To initiate printing, press the data transfer key. Data may

Seite 28

- 33 - Scale→Computer: no response,  Example: To set 1000g in weight B1.5 (d=0.5g) type: S L 1 0 0 0 . 0 CR LF (53h 4Ch 31h 30h 30h 30h 2Eh 30h 0

Seite 29 - 30 other

- 34 - 15.2. Baud Rate 1. Press the Menu key, when the option “Port - 1” is displayed press the T key, and then select the option “Baud” by press t

Seite 30

- 35 - 15.4. Parity 1. Press the MENU key, when the option “Port - 1” is displayed press the T key, and then select the option “Parity” by press th

Seite 31

- 36 - A detailed transaction receipt can be printed after weighing has been completed. The receipt can be customized to include the following info

Seite 32

- 37 - 16.1. Enabling and Disabling Receipt Fields 1. Press the MENU key, when the option “Print” is displayed press the T key, and then select a

Seite 33

- 38 - Function Options: LOC Off ( LOC oFF) Disables the LOC Dynamic Weighing Function LOC On (LOC on) Enables and Starts the LOC Dynamic Weighi

Seite 34

- 3 - CAUTION: • The scale is designed for indoor use only. • Do not operate the scale in hazardous areas or conditions. • Do not use the scale i

Seite 35 - 4800 9600 19200 38400

- 39 - 18.1. Storing a Tare Value Manually 1. Press the MENU key, when the option “Tare” is displayed press the T key, and then select the option

Seite 36

- 40 - 18.2. Storing a Tare Value Automatically 1. Place a container on the pan and press the MENU key to enter the main menu. 2. When the

Seite 37

- 41 - 18.3. Recalling a previously stored tare value. 1. Press the MENU key, when the option “Tare” is displayed press the T key, and then select

Seite 38 - 0.00 IDPRoD

- 42 - This function allows you to find the maximum (highest) or minimum (lowest) weight in a series of weights. 1. Press the MENU key. When th

Seite 39 - LOC LOC oN

- 43 - This function changes the unit of weight to Newton (N) - 1N ≈0.101971 kg 1. Press the MENU key, when the option “Newton” is displayed pre

Seite 40

- 44 - This function is used when vibration is encountered during weighing. This may be the result of ground vibration, or a vibrating live load o

Seite 41

- 45 - Function Options: Dat On (DAT oN) Enables date and time printing with every weighing result. Dat Off (DAToff) Disables date and time printi

Seite 42

- 46 - 2. The current time will be displayed. To change or to set a new time press the T key 3. Use the following keys to change the

Seite 43

- 47 - 7. Once the time has been set the scale will display the current year. To change the years press the T key. 22.3. Enabling PIN acce

Seite 44

- 48 - Threshold check weighing is used to check whether a weight of an object falls within specified threshold limits. Function Options: Thr Off

Seite 45

- 4 - Follow all safety guidelines in order to avoid electrical shock, or damage to connected peripheral devices.

Seite 46 - Date DATSET

- 49 - 4. After setting all limit sets, select “Set-0” in order to return to weighing with the limits enabled. 5. To perform check weighi

Seite 47

- 50 - 23.2. Setting the output mode for the opto-isolator (Pulse Mode / Level Mode). Output signals are provided for controlling sorting or signali

Seite 48 - Date DATPIN

- 51 - 2. The scale will display options “Impuls” and” Signal”. To select Pulse Mode press the T key when “Impuls” is displayed, to select Signal Mo

Seite 49

- 52 - Function Options: Tot Prn (totPRN) Displays and prints transaction total. (Does not reset the sum value) Tot Off (totoff) Displays and dis

Seite 50

- 53 - 4. Once the weight has been added, remove the object from the weighing pan. 5. Wait for the scale to return to 0 and place the second ob

Seite 51

- 54 - The function “lb bal” is used to configure the unit to weigh in grams (g) or pounds (lb). “Lb Bal” optimize the scale’s accuracy and resolu

Seite 52 - IMMPUL SIGNAL

- 55 - The Active function is used to customize the scale’s Main Menu. This feature should be used to deactivate functions or features that are not

Seite 53

- 56 - Error or Indicator Cause Explanation / Solution - - - - Below zero Re-zero the scale by pressing the Æ0Å key. - - Taring is not allowed

Seite 54

- 57 - PURCHASER’S 12-MONTH WARRANTY Warranty is valid only if the attached warranty registration card is completed and returned within 30 days.

Seite 55 - Lb off Lb on

Fulcrum Inc. 100 Delawanna Ave.,#120 Clifton, NJ 07014 (973) 473 6900 (973) 777 8302 http://www.fulcruminc.net

Seite 56

- 5 - Table 1. Economy Series and Remote Mount Series Model Number - BA Specification 30C 60C 153C 303C 30E 60E 150E 3U 6U 15U Capacity Kg/lb

Seite 57 - Chapter 29: Maintenance

- 6 - Key Primary Function Power On and Power Off ÆTÅ Tare – used to tare the weighing pan Æ0Å Zero – used to zero the scale (Legal for Trade

Seite 58

- 7 - BA Models: Front View Rear View Indicator Pan Base Pan AC Adapter RS232 and Output Port Column Level Indicator AC Ad

Seite 59

- 8 - 1. Carefully remove the scale, pan, and all of its components out of the packaging and place them on a stable surface where the scale will

Kommentare zu diesen Handbüchern